Experimental investigation of discharge capacity of labyrinth weirs with and without nappe breakers

Basit öğe kaydını göster

dc.contributor.author Bilhan, Ömer
dc.contributor.author Emiroğlu, M. Emin
dc.contributor.author Miller, Carol
dc.date.accessioned 2021-07-07T07:38:02Z
dc.date.available 2021-07-07T07:38:02Z
dc.date.issued 2016-07-29
dc.identifier.uri http://hdl.handle.net/20.500.11787/3640
dc.description.abstract Labyrinth weirs provide higher discharge capacity than conventional weirs, with the ability to pass large flows at comparatively low heads. Labyrinth weirs are primarily used as spillways for dams where the spillway width is restricted. In recent years, many research investigations have considered the hydraulic performance of labyrinth weirs, particularly as dependent on the geometric features. The previous work has improved the design basis for such weirs. However, their design still requires experimentally derived and generalized performance curves. It is especially important to observe the behavior of the weir nappe to ensure the design provides hydraulic optimization and to account for pressure fluctuations, possible vibrations, resonance effect, noise and flow surging. In the present study, discharge coefficients were experimentally determined for both circular labyrinth weirs and sharp crested trapezoidal labyrinth weirs of varying side wall angle (α). Additional studies were completed with nappe breakers included to reduce the impact of vibration on the labyrinth weirs. In general, the test data indicated that nappe breakers placed on the trapezoidal labyrinth weirs and circular labyrinth weirs reduced the discharge coefficient by up to 4% of the un-amended weir. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.4236/wjm.2016.67017 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Weir tr_TR
dc.subject Discharge Coefficient tr_TR
dc.subject Trapezoidal tr_TR
dc.subject Circular tr_TR
dc.subject Labyrinth Weir tr_TR
dc.subject Nappe Breaker tr_TR
dc.title Experimental investigation of discharge capacity of labyrinth weirs with and without nappe breakers tr_TR
dc.type article tr_TR
dc.relation.journal World Journal of Mechanics tr_TR
dc.contributor.department Nevşehir Hacı Bektaş Veli Üniversitesi Mühendislik Mimarlık Fakültesi İnşaat Mühendisliği Bölümü tr_TR
dc.contributor.authorID 0000-0002-8661-6097 tr_TR
dc.contributor.authorID 100616 tr_TR
dc.identifier.volume 6 tr_TR
dc.identifier.startpage 207 tr_TR
dc.identifier.endpage 221 tr_TR


Bu öğenin dosyaları

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster