dc.description.abstract |
Purpose: The purpose of this study was to
compare the sealing ability of temporary
restorative materials at 24 hrs and 1 week.
Materials and Methods: Endodontic access cavities
were prepared in 56 extracted lower incisor-teeth
and divided into 5 groups (n=10). Standard 5 mm
deep access preparations were completed and root
canals were prepared to size ISO #30 file. The access
cavities were restored as follows: Group 1: temporary
restorative material (Ceivitron); Group 2: glass ionomer
cement (Fuji II); Group 3: zinc oxide-eugenol cement
(IRM); Group 4: zinc phosphate cement (Adhesor);
Group 5: polytetrafluoroetylene tape (PTFE). The
quality of the coronal sealing of each specimen was
measured (24 hrs and 1 week) using fluid transport
model. The data was analysed with repeated
measurements of ANOVA, Tukey, Paired samples T-Tests.
Results: A significant difference was found among
the groups at all time-periods (p<0.05). At 24 hrs,
PTFE showed similar leakage with Ceivitron, IRM,
and Fuji II but it showed higher leakage than Adhesor.
At 1 week, Ceivitron showed higher leakage than
PTFE, meanwhile PTFE showed similar leakage
with IRM, Fuji II, and Adhesor (p>0.05). Sealing
ability of IRM and PTFE groups significantly
increased by time (p<0.05 and p<0.001 respectively).
Conclusion: Within the limitations of this study, PTFE
showed an acceptable short-term sealing capability
when compared to the other commonly used temporary
restorative materials at 1 week measurements. |
tr_TR |
dc.language.iso |
eng |
tr_TR |
dc.relation.isversionof |
https://dx.doi.org/10.17096/jiufd.08659 |
tr_TR |
dc.rights |
info:eu-repo/semantics/openAccess |
tr_TR |
dc.subject |
Dental leakage |
tr_TR |
dc.subject |
Polytetrafluoroethylene |
tr_TR |
dc.subject |
Temporary dental fillings |
tr_TR |
dc.subject |
Dental sızıntı |
tr_TR |
dc.subject |
Politetrafloroetilen |
tr_TR |
dc.subject |
Geçici dolgu maddeleri |
tr_TR |
dc.title |
Geçici restoratif dolgu materyali olarak politetrafloroetilen bant (ptfe): Sıvı filtrasyon çalışması |
tr_TR |
dc.title.alternative |
Geçici restoratif dolgu materyali olarak Polytetrafluoroetylene tape as temporary restorative material: A fluid filtration study bant (ptfe): Sıvı filtrasyon çalışması |
tr_TR |
dc.type |
article |
tr_TR |
dc.relation.journal |
Journal of Istanbul University Faculty of Dentistry |
tr_TR |
dc.contributor.department |
Nevşehir Hacı Bektaş Veli Üniversitesi/diş hekimliği fakültesi/klinik bilimler bölümü/endodonti anabilim dalı |
tr_TR |
dc.contributor.authorID |
311964 |
tr_TR |
dc.identifier.volume |
49 |
tr_TR |
dc.identifier.issue |
3 |
tr_TR |
dc.identifier.startpage |
17 |
tr_TR |
dc.identifier.endpage |
22 |
tr_TR |