Passive–active integrators chaotic oscillator with anti-parallel diodes: analysis and its chaos-based encryption application to protect electrocardiogram signals

Basit öğe kaydını göster

dc.contributor.author Pone, Justin Roger Mboupda
dc.contributor.author Çiçek, Serdar
dc.contributor.author Takougang Kingni, Sifeu
dc.contributor.author Tiedeu, Alain
dc.contributor.author Kom, Martin
dc.date.accessioned 2021-04-20T15:07:25Z
dc.date.available 2021-04-20T15:07:25Z
dc.date.issued 2020
dc.identifier.citation J. R. M. Pone, S. ÇİÇEK, S. T. Kingni, A. Tiedeu, and M. Kom, “Passive active integrators chaotic oscillator with anti parallel diodes analysis and its chaos based encryption application to protect electrocardiogram signals,” ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, vol. 103, no. 1, pp. 1–15, Apr. 2020. tr_TR
dc.identifier.uri https://link.springer.com/article/10.1007/s10470-019-01557-0
dc.identifier.uri http://hdl.handle.net/20.500.11787/1318
dc.description.abstract An autonomous passive–active integrators oscillator with anti-parallel diodes is proposed and analysed in this paper. It consists of anti-parallel diodes and two main blocks: A second-order passive RLC integrator and a first-order active RC integrator. The existence of two Hopf bifurcations is established during the stability analysis of the unique equilibrium point. For a suitable choice of the circuit parameters, the proposed oscillator can generate periodic oscillations, one-scroll, bistable chaotic attractors and antimonotonicity. The electronic circuit realization of the proposed oscillator is carried out to confirm results found during the numerical simulations. A good qualitative agreement is illustrated between the numerical simulations and experimental results. In addition, chaos-based encryption application to protect electrocardiogram (ECG) signals for secure transmission of medical information is performed using the proposed oscillator in chaotic regime. The ECG signals are successfully encrypted and the original ECG signal is successfully decrypted from noisy ECG signals. tr_TR
dc.language.iso eng tr_TR
dc.publisher Springer tr_TR
dc.relation.isversionof 10.1007/s10470-019-01557-0(0123456789().,-volV)(0123456789,-().volV) tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject Passive–active integrator oscillator tr_TR
dc.subject Anti-parallel diodes tr_TR
dc.subject Hopf bifurcation tr_TR
dc.subject Bistable chaotic attractors tr_TR
dc.subject Electronic circuit experiment tr_TR
dc.subject Chaos-based encryption of ECG signals tr_TR
dc.title Passive–active integrators chaotic oscillator with anti-parallel diodes: analysis and its chaos-based encryption application to protect electrocardiogram signals tr_TR
dc.type article tr_TR
dc.relation.journal Analog Integrated Circuits and Signal Processing tr_TR
dc.contributor.department Nevşehir Hacıbektaş Veli Üniversitesi, Hacıbektaş Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümü tr_TR
dc.contributor.authorID 33672 tr_TR
dc.identifier.volume 103 tr_TR
dc.identifier.startpage 1 tr_TR
dc.identifier.endpage 15 tr_TR