Deep level transient spectroscopy and pulse height measurements on high resolution n-type 4H-SiC epitaxial schottky barrier radiation detectors

Basit öğe kaydını göster

dc.contributor.author Oner, Cihan
dc.contributor.author Chowdhury, Towhid A.
dc.contributor.author Santi, Enrico
dc.contributor.author Mandal, Krishna C.
dc.date.accessioned 2023-12-21T06:36:05Z
dc.date.available 2023-12-21T06:36:05Z
dc.date.issued 2017
dc.identifier.citation C. Oner, T. A. Chowdhury, E. Santi and K. C. Mandal, "Deep Level Transient Spectroscopy and Pulse Height Measurements on High Resolution n-Type 4H-SiC Epitaxial Schottky Barrier Radiation Detectors," 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Atlanta, GA, USA, 2017, pp. 1-5, doi:10.1109/NSSMIC.2017.8532837. tr_TR
dc.identifier.uri http://hdl.handle.net/20.500.11787/8342
dc.description.abstract High resolution 20 μm n-type 4H-SiC epitaxial layer Schottky barrier radiation detectors were fabricated by depositing nickel (Ni) contacts using DC sputtering for both front- and backside. Current-Voltage (I-V) measurements at 300 K showed barrier height and diode ideality factor of ~1.14 eV and 1.19 respectively. The leakage current at -170 V reverse bias was ~1.0 × 10 -9 A. Capacitance-Voltage (C-V) measurements revealed a doping concentration of 2.9 × 10 14 cm -3 . Deep level transient spectroscopy (DLTS) was carried out to investigate defect levels and capture cross sections. Shallow and deep level defects at Ec - (0.14 ± 0.01) eV, Ec - (0.18 ± 0.01) eV, Ec - (0.62 ± 0.02) eV, Ec - (1.42 ± 0.04) eV, and Ec - (1.52 ± 0.03) eV have been found. A 0.1 μCi 241 Am radiation source was used to assess the detector performance by pulse height spectroscopy (PHS) and the detector showed energy resolution of 0.38% full-width half maxima (FWHM) for alpha particles at 5447 keV. tr_TR
dc.description.sponsorship This work was partly supported by the DOE Office of Nuclear Energy’s Nuclear Energy University Program, Grant No. DE-NE0008662 and also by the Advanced Support Program for Innovative Research Excellence-I (ASPIRE-I) of the University of South Carolina, Columbia, Grant No. 15530-E404. tr_TR
dc.language.iso eng tr_TR
dc.publisher IEEE tr_TR
dc.relation.isversionof 10.1109/NSSMIC.2017.8532837 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject SiC tr_TR
dc.subject Detector tr_TR
dc.subject Radiation tr_TR
dc.subject DLTS tr_TR
dc.subject PHS tr_TR
dc.subject SBD tr_TR
dc.title Deep level transient spectroscopy and pulse height measurements on high resolution n-type 4H-SiC epitaxial schottky barrier radiation detectors tr_TR
dc.type conferenceObject tr_TR
dc.relation.journal 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) tr_TR
dc.contributor.department Elektrik-Elektronik Mühendisliği Bölümü tr_TR