Design and response testing of Boron-Diffused silicon carbide neutron detectors for Dosimetry and Monitoring applications

Basit öğe kaydını göster

dc.contributor.author Mandal, Krishna C.
dc.contributor.author Chowdhury, Towhid A.
dc.contributor.author Oner, Cihan
dc.contributor.author Ruddy, Frank H.
dc.date.accessioned 2023-12-21T06:35:14Z
dc.date.available 2023-12-21T06:35:14Z
dc.date.issued 2018-12-14
dc.identifier.citation Mandal, K. C., Chowdhury, T. A., Oner, C., and Ruddy, F. H., “Design and Response Testing of Boron-Diffused Silicon Carbide Neutron Detectors for Dosimetry and Monitoring Applications,”Reactor Dosimetry: 16th International Symposium, ASTM STP1608, M.H.Sparks,K.R.DePriest,and D. W. Vehar, Eds., ASTM International, West Conshohocken, PA, 2018, pp. 353–360, http://dx.doi.org/10.1520/STP160820170042 tr_TR
dc.identifier.uri http://hdl.handle.net/20.500.11787/8340
dc.description.abstract A high-sensitivity boron-diffused silicon carbide (4H-SiC) p-n diode has been designed and fabricated using vapor-phase epitaxy. Boron-10 (10B) is diffused into nitrogen-doped n- SiC, forming the p+ layer, and thermal neutrons are detected through the ionization produced in the detector by 10B(n,a) 7Li reactions. These detectors have been tested with thermalized neutrons from an isotopic californium-252 (252Cf) source and have been shown to provide a robust pulse-height spectrum, which is easily separable from the anticipated gamma-ray response. The detectors are expected to be useful for neutron and gamma-ray fluence rate measurements in high gamma-ray fields for extended times at temperatures up to 700C. tr_TR
dc.description.sponsorship This work was supported in part by the Department of Energy, Office of Nuclear Energy’s Nuclear Energy University Programs, Grant No. DE-AC07-051D14517 and also by Advanced Support for Innovative Research Excellence-I (ASPIRE-I) of the University of South Carolina, Columbia, Grant No. 15530-E404. tr_TR
dc.language.iso eng tr_TR
dc.publisher ASTM INTERNATIONAL tr_TR
dc.relation.isversionof 10.1520/STP1608-EB tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject SiC tr_TR
dc.subject Neutron tr_TR
dc.subject Detector tr_TR
dc.subject Boron tr_TR
dc.subject Neutron Converter tr_TR
dc.subject Radiation tr_TR
dc.subject Response tr_TR
dc.subject Silicon Carbide tr_TR
dc.title Design and response testing of Boron-Diffused silicon carbide neutron detectors for Dosimetry and Monitoring applications tr_TR
dc.type bookPart tr_TR
dc.relation.journal Reactor Dosimetry: 16th International Symposium tr_TR
dc.contributor.department Elektrik-Elektronik Mühendisliği Bölümü tr_TR
dc.contributor.authorID 298671 tr_TR
dc.contributor.authorID 0000-0003-4967-9598 tr_TR
dc.identifier.startpage 353 tr_TR
dc.identifier.endpage 360 tr_TR