Mandal, K. C., Chowdhury, T. A., Oner, C., and Ruddy, F. H., “Design and Response Testing of Boron-Diffused Silicon Carbide Neutron Detectors for Dosimetry and Monitoring Applications,”Reactor Dosimetry: 16th International Symposium, ASTM STP1608, M.H.Sparks,K.R.DePriest,and D. W. Vehar, Eds., ASTM International, West Conshohocken, PA, 2018, pp. 353–360, http://dx.doi.org/10.1520/STP160820170042 |
tr_TR |
dc.identifier.uri |
http://hdl.handle.net/20.500.11787/8340 |
|
dc.description.abstract |
A high-sensitivity boron-diffused silicon carbide (4H-SiC) p-n diode has been designed and fabricated using vapor-phase epitaxy. Boron-10 (10B) is diffused into nitrogen-doped n- SiC, forming the p+ layer, and thermal neutrons are detected through the ionization produced in the detector by 10B(n,a) 7Li reactions. These detectors have been tested with thermalized neutrons from an isotopic californium-252 (252Cf) source and have been shown to provide a robust pulse-height spectrum, which is easily separable from the anticipated gamma-ray response. The detectors are expected to be useful for neutron and gamma-ray fluence rate measurements in high gamma-ray fields for extended times at temperatures up to 700C. |
tr_TR |
dc.description.sponsorship |
This work was supported in part by the Department of Energy, Office of Nuclear
Energy’s Nuclear Energy University Programs, Grant No. DE-AC07-051D14517 and
also by Advanced Support for Innovative Research Excellence-I (ASPIRE-I) of the
University of South Carolina, Columbia, Grant No. 15530-E404. |
tr_TR |
dc.language.iso |
eng |
tr_TR |
dc.publisher |
ASTM INTERNATIONAL |
tr_TR |
dc.relation.isversionof |
10.1520/STP1608-EB |
tr_TR |
dc.rights |
info:eu-repo/semantics/openAccess |
tr_TR |
dc.subject |
SiC |
tr_TR |
dc.subject |
Neutron |
tr_TR |
dc.subject |
Detector |
tr_TR |
dc.subject |
Boron |
tr_TR |
dc.subject |
Neutron Converter |
tr_TR |
dc.subject |
Radiation |
tr_TR |
dc.subject |
Response |
tr_TR |
dc.subject |
Silicon Carbide |
tr_TR |
dc.title |
Design and response testing of Boron-Diffused silicon carbide neutron detectors for Dosimetry and Monitoring applications |
tr_TR |
dc.type |
bookPart |
tr_TR |
dc.relation.journal |
Reactor Dosimetry: 16th International Symposium |
tr_TR |
dc.contributor.department |
Elektrik-Elektronik Mühendisliği Bölümü |
tr_TR |
dc.contributor.authorID |
298671 |
tr_TR |
dc.contributor.authorID |
0000-0003-4967-9598 |
tr_TR |
dc.identifier.startpage |
353 |
tr_TR |
dc.identifier.endpage |
360 |
tr_TR |