dc.description.abstract Sampling of salivary cortisol and amylase is a non-invasive method and important for the evaluation of the hypothalamic–pituitary–adrenal axis function and stress levels. This study aimed to compare the values of the salivary cortisol and amylase levels which were measured by three diferent analytical methods to discuss the alterations of stress levels of samples. The saliva samples of young adults (n=23) were collected between 08.00 and 09.00 a.m., noon at 12.00 (before exam) and between 14.00 and 15.00 p.m. (after unaware exam). The samples were measured within the frst 48 h, and no freezing/thawing was done. Salivary cortisol and amylase levels of subjects were measured by three diferent analytical methods as ELISA, chemiluminescence and biosensor methods. Comparison of ELISA and biosensor methods in order to determine the salivary cortisol levels showed a good correlation y=2.971+0.748x (R2=0.839). Salivary amylase concentrations were only detected by ELISA method. Biosensor can be ofered as an alternative analytic method to the conventional determination method ELISA. It can be preferred because of the detection/information efectiveness, low cost, fast results and specifcity characteristics. tr_TR
dc.language.iso eng tr_TR
dc.publisher Springer tr_TR
dc.relation.isversionof 10.1007/s12010-021-03676-9 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Saliva tr_TR
dc.subject Cortisol tr_TR
dc.subject Amylase tr_TR
dc.subject Biosensor tr_TR
dc.subject ELISA tr_TR
dc.subject Chemiluminescence tr_TR
dc.subject Stress tr_TR
dc.title The saliva cortisol and amylase levels related with stress response compared by different analytical methods tr_TR
dc.type article tr_TR
dc.relation.journal Applied Biochemistry and Biotechnology tr_TR
dc.contributor.department Nevşehir Hacı Bektaş Veli Üniversitesi/diş hekimliği fakültesi/temel bilimler bölümü/temel tıp bilimleri anabilim dalı tr_TR
dc.contributor.authorID 158848 tr_TR
dc.identifier.volume 194 tr_TR
dc.identifier.startpage 1166 tr_TR
dc.identifier.endpage 1177 tr_TR


Bu öğenin dosyaları

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster