Biodegradability of slaughterhouse wastewater with high blood content under anaerobic and aerobic conditions

Basit öğe kaydını göster

dc.contributor.author Del Pozo, Rodrigo
dc.contributor.author Okutman Taş, Didem
dc.contributor.author Dulkadiroğlu, Hakan
dc.contributor.author Orhon, Derin
dc.contributor.author Diez, Victorino
dc.date.accessioned 2021-08-24T08:55:50Z
dc.date.available 2021-08-24T08:55:50Z
dc.date.issued 2003-04
dc.identifier.uri http://hdl.handle.net/20.500.11787/4232
dc.description.abstract Abstract: In this work, the biodegradability of wastewater from a slaughterhouse located in Keşan, Turkey, was studied under aerobic and anaerobic conditions. A very high total COD content of 7230mg dm-3 was found, due to an inefficient blood recovery system. Low BOD5/COD ratio, high organic nitrogen and soluble COD contents, were in accordance with a high blood content. A respirometry test for COD fractionation showed a very low readily biodegradable fraction (SS) of 2%, a rapidly hydrolysable fraction (SH) of 51%, a slowly hydrolysable fraction (XS) of 33% and an inert fraction of 6%. Kinetic analysis revealed that hydrolysis rates were much slower than these of domestic sewage. The results underlined the need for an anaerobic stage prior to aerobic treatment. Tests with an anaerobic batch reactor indicated efficient COD degradation, up to around 80% removal. Further anaerobic degradation of the remaining COD was much slower and resulted in the build up of inert COD compounds generated as part of the metabolic activities in the anaerobic reactor. Accordingly, it is suggested that an appropriate combination of anaerobic and aerobic reactors would have to limit anaerobic degradation to around 80% of the tCOD and an effluent concentration above 1000mg dm-3, for the optimum operation of the following aerobic stage. tr_TR
dc.language.iso eng tr_TR
dc.publisher WILEY tr_TR
dc.relation.isversionof 10.1002/jctb.753 tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject Hydrolysis tr_TR
dc.subject Modelling tr_TR
dc.subject Residual COD tr_TR
dc.subject Respirometry tr_TR
dc.subject Slaughterhouse tr_TR
dc.subject Aerobic–anaerobic treatment tr_TR
dc.title Biodegradability of slaughterhouse wastewater with high blood content under anaerobic and aerobic conditions tr_TR
dc.type article tr_TR
dc.relation.journal JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY tr_TR
dc.contributor.department Nevşehir Hacı Bektaş Veli Üniversitesi/mühendislik-mimarlık fakültesi/çevre mühendisliği bölümü/su kirliliği ve atıksu kontrol teknolojisi anabilim dalı tr_TR
dc.contributor.authorID 238208 tr_TR
dc.identifier.volume 78 tr_TR
dc.identifier.issue 4 tr_TR
dc.identifier.startpage 384 tr_TR
dc.identifier.endpage 391 tr_TR


Bu öğenin dosyaları

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster