dc.description.abstract |
One of the most commonly used control methods is a tuned mass damper (TMD), which is often employed to mitigate the amplitude of mechanical vibrations. To get a more effective response reduction of the structure, it is essential that the dynamics of the structure are modeled as accurately as possible. In this study, the seismic response of a reinforced concrete (RC) six-story building was analyzed with the combinations of masonry infill-wall, a passive and an active tuned mass damper (ATMD). The infill walls were placed along all frames without any space between column-wall and beam-wall connection. The TMD has no external source of energy, while the ATMD has an external energy source generated by the actuator which is driven by a linear quadratic regulator (LQR) controller. The dynamic response of the building was evaluated using the data from a real earthquake excitation of El Centro in 1940. The results highlight the inclusion of masonry infill wall in the seismic analysis is very important and has a substantial effect on the fundamental frequency and seismic characteristic of the structure. It also has a significant impact on the reduction of the inter-story drift and the seismic energy performance of the building. |
tr_TR |
dc.language.iso |
eng |
tr_TR |
dc.publisher |
Journal of Computers & Structures |
tr_TR |
dc.relation.isversionof |
10.1016/j.compstruc.2019.07.006 |
tr_TR |
dc.rights |
info:eu-repo/semantics/openAccess |
tr_TR |
dc.subject |
Tuned mass damper (TMD) |
tr_TR |
dc.subject |
Active tuned mass dampe(ATMD) |
tr_TR |
dc.subject |
Linear quadratic regulator (LQR) |
tr_TR |
dc.subject |
Masonry infill wall |
tr_TR |
dc.subject |
Reinforced concrete (RC) |
tr_TR |
dc.subject |
Building |
tr_TR |
dc.title |
Performance evaluation of a reinforced concrete building strengthened respectively by the infill wall, active and passive tuned mass damper under seismic load |
tr_TR |
dc.type |
article |
tr_TR |
dc.contributor.department |
Nevşehir Hacı Bektaş Veli Üniversitesi/mühendislik-mimarlık fakültesi/inşaat mühendisliği bölümü/yapı anabilim dalı |
tr_TR |
dc.contributor.authorID |
311166 |
tr_TR |
dc.identifier.volume |
223 |
tr_TR |
dc.identifier.issue |
106097 |
tr_TR |
dc.identifier.startpage |
1 |
tr_TR |
dc.identifier.endpage |
11 |
tr_TR |